OMRON
Home >> Supply >> CJ1W-PD025 OMRON CJ1W-PD025
Search
Information sort

CJ1W-PD025 OMRON CJ1W-PD025


Protector for Expansion I/O Rack IOIF connector CV500-COV02Model: C200H-MR833.
Description: RAM, 8K words, battery back-up.with clock(CPU21, CPU23 only).
Product name: DC Power Supply Unit.
Power supply voltage: 24 VDC. 5A;
24-VDC output capacity, 0.8A;
Total power consumption, 25w CJ1W-PD025.
Options: 24-VDC service power supply, No;
RUN output, No; Maintenance forecaast monitor, No.
Standards: UC1, N, L, CE.
Equipped with the RUN output for,
checking the operation status,
as well as the replacement CJ1W-PD025.
notification function for easy,
maintenance.
Lineup of five models including the,
AC power supply (25W).
Stable power supply is available from the,
CJ-series CPU Unit to each I/O Units via the,
dedicated bus. The most suitable Power Supply,
Unit can be selected among various I/O ,
specifications and/or options CJ1W-PD025. Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Transistor (sourcing).
Program capacity: 8K steps OMRON CJ1W-PD025.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.27A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality OMRON CJ1W-PD025.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508 OMRON CJ1W-PD025.4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CJ1W-PD025.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.