Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Single-loop standard control Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Pulse voltage and Pulse voltage/current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, RS-485 E5AN-HAA2HHBFM-500 User's Manual.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity
E5AN-HAA2HHBFM-500
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller E5AN-HAA2HHBFM-500 User's Manual.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming E5AN-HAA2HHBFM-500 User's Manual. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type.
Polarity: none.
Shape: shield, M18.
Detection range: 7mm.
Action mode: NO. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Tempeerature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AN-HAA2HHBFM-500 MANUAL.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AN-HAA2HHBFM-500 MANUAL.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.