Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 48 x 96mm.
Control output 1: relay output (open).
Control output 2: relay output (off) E5CN-HR2H03-W-FLK USER'S MANUAL.
Auxiliary output: 2.
Communication mode: RS-485
E5CN-HR2H03-W-FLK
Heater disconnection: 2.
Event input: -.
Plug in terminal: -.
Potentiometer input: there.
Power supply voltage: AC100 ~ 240V.
New highlight LCD panel, font larger, display more clearly integrated low power design,
Longer life performance stability,
Perfect function of proportional valve control special (some models have no potentiometer input virtual opening function)
E5AC-PR-800 white LCDPV display height to reach 25mm, greatly improve the visibility E5CN-HR2H03-W-FLK USER'S MANUAL.
The main body is short, and the diameter is only 60mm.
50ms high speed sampling period. Small, easy to use.
Detection method: Regression reflection type.
Shape: vertical type.
Connection mode: lead wire.
Detection distance: 1 meters of red light E5CN-HR2H03-W-FLK USER'S MANUAL.
Output mode: NPN output. Name: Laser Reflectors, Standard.
Ambient operating temperature range: -10 to 55°C (No icing).
Ambient storage temperature range: -25 to 70°C (No icing).
Ambient operating humidity range: 35 to 85% (No condensation).
Ambient storage humidity range: 35 to 85% (No condensation). Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5CN-HR2H03-W-FLK MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HR2H03-W-FLK MANUAL.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.