Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-Q2H03TD-W-FLK User's Manual.
Ideal for the thermal input devices of Temperature Controllers
E5CN-Q2H03TD-W-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Detection mode: diffuse reflection type.
Connection: socket type (M12).
Detection range: red light 100mm.
Output mode: NPN output E5CN-Q2H03TD-W-FLK User's Manual. Sensing method: Through-beam type.
Sensing distance(slot width): 3.6 mm.
Output type: NPN output.
Output configuration: Light-ON.
Cable length: 1 m.
Photomicrosensor with built-in,
amplifier and attached cable reduces,
external light interference.
Light modulation effectively reduces external light interference.
Wide operation voltage range: 5 to 24 VDC.
Easy operation monitoring with bright light indicator E5CN-Q2H03TD-W-FLK User's Manual. Sensing method: Through-beam.
Connection method: Pre-wired (2 m).
Sensing distance: 25 mm.
No. of opti- cal axes: 2.
Model: NPN output.
Photoelectric Sensor with Grooved.
Design and Easy Settings .
Groove-type Sensor with groove width of 25 mm.
Models are available with one or two light axes.
Models are available with M8 pre-wired connectors. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: 1 loop for standard control,
Single-loop heating and cooling control.
Outputs(control/transfer): 4 points: Pulse voltage and Pulse,
voltage/current and Current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models wwith CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5CN-Q2H03TD-W-FLK MANUAL. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5CN-Q2H03TD-W-FLK MANUAL.
DeviceNet Communications.