CPU Unit: CP1L-M CPU Units with 60 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 36; Output, 24 CP1E-N14DR-D USER'S MANUAL.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet
CP1E-N14DR-D
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. CPU Unit: CP1L-M CPU Units with 60 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 36; Output, 24 CP1E-N14DR-D USER'S MANUAL.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port CP1E-N14DR-D USER'S MANUAL.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. For C200H-PRO27-E Hand-held Programming Console ming Console.
4m.Name: SYSMAC LINK Module.
Model: C200HW-SLK14.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Daisy chain.
Weight: 500g max.Can be used for backing up programs or auto-booting.Model: CPM2C-20CDTC-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Accessory Battery C500-BAT08(3G2A5-BAT08)Model: C500-BC081(3G2A5-BC081).
8 slots(3 linkable slots).
Name: Wired Master.
Model: C200H-RM201.Model: C1000H-TER01.
Each node requires one of the ends of the network.Inputs: 8.I/O Control UnitName: Analog I/O Slave Units,
(Numerical indicator type)
MIL Connector Type.
Specifications: Analog outputs; 2 outputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost caan be reduced CP1E-N14DR-D Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1E-N14DR-D Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.