Provided with SYSMAC LINK Unit.Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 8outputs;
Maximum switching capacity, 24VDC,
2AShort-circuit protection;
Commons, 4 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word CPM1A-30CDT1-D-V1 User's Manual.
Current consumption: 5V, 0.11A; 24V, --.
Standards: UC1, N, L, CE
CPM1A-30CDT1-D-V1
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput CPM1A-30CDT1-D-V1 User's Manual. I/O capacity: 2.048 pts (6, 144 max. with remote I/O).
Execution time: Basic: 0.125 µs min.Special: 0.5 µs min.
Name: External Connector.
Model: C500-CE404.
Specifications: Solder terminal; 40p and a Connector Cover (Horizontal-type).Model: C200H-OC226N.
No. of points: 16 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Name: Compact Connectors.
Specifications: Inputs/Outputs; 1 input/1 output; PNP CPM1A-30CDT1-D-V1 User's Manual.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. 4 thermocouple inputsModel: C500-BC031(3G2A5-BC031).
3 slots(3 linkable slots).
Specification: Platinum resistance thermometer input (Pt, JPt),
ON/OFF or advanced PID control,
tran-sistor (PNP) output, 2 loops.Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Units with EtherCAT interface.
Specifications: Control output interface,
Control commands executed by,
EtherCAT communications.
Positioning functions: Memory operation,
Direct operation by ladder programming;
No. of axes: 4 axes.
No. of unit numbers allocated:: 1 CPM1A-30CDT1-D-V1 Manual.
Current consumption : 5V, 0.46A; 24V,--.
Standards: UC1, CE.
Preeminent control performance and,
easy operation feature of EtherCAT,
improve the production efficiency.
The EtherCAT communications with,
100Mbps bbaud rate enables fast,
and accurate position control CPM1A-30CDT1-D-V1 Manual.
A wide range of position control,
functions are available with,
this position control unit.