I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
ABS interface: Yes.Model: C200H-OD21A.
No. of points: 16 pts.
Specifications: 1.0 A, 24 VDC. source type (PNP). with load short protection.Name: CS1D CPU Backplane.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Number of Power Supply Units,
2 Units max CS1W-PTS11 User's Manual
CS1W-PTS11 (for duplex operation);
Number of I/O Units, 5 Units max.
(including the I/O Control Units).
Current consumption: 5V system, 1.20A;
26V system, --.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.Name: SYSMAC LINK Module.
Model: C200HW-SLK24 CS1W-PTS11 User's Manual.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Bus.
Weight: 400 g max.Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CS1W-PTS11 User's Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: CPM2C-8ER. Units with relay outputs only.
I/O terminal block.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.I/O bits: 1, 280 (Expan-sion Racks: 3).
Program capacity: 30K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 bank)Model: CPM2C-8EDM. Units with inputs only.
1 MIL connector.
Inputs: 8 inputs.
Outputs: ---.
Input type: 24 VDC.
Output type: --.Name: Two-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CS1W-PTS11 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1W-PTS11 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.