OMRON
Home >> Download >> OMRON >> Manual Download >> E5AC-CX3DSM-800 User's Manual ()

E5AC-CX3DSM-800 User's Manual ()

Brand: OMRON
Product model: E5AC-CX3DSM-800
Name: OMRON E5AC-CX3DSM-800 User's Manual
Sort: User's Manual
File language: English
File size: 6.47MB
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5AC-CX3DSM-800 User's Manual.
Event entry point: 2.
Transfer output: transfer output (special terminal) E5AC-CX3DSM-800
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C E5AC-CX3DSM-800 User's Manual.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5AC-CX3DSM-800 User's Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtherr performance improvement E5AC-CX3DSM-800 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5AC-CX3DSM-800 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller
E5AC-CX2ASM-013
OMRON Digital temperature controller E5AC-CX2ASM-013
Size: 96 x 96mm. Control output 1: linear cu
OMRON
Digital Temperature Controller
E5CC-CX2DSM-800
OMRON Digital Temperature Controller E5CC-CX2DSM-800
Control output 1: Linear current output. Aux
OMRON
Digital temperature controller
E5AC-CX2ASM-000
OMRON Digital temperature controller E5AC-CX2ASM-000
Size: 96 x 96mm. Control output 1: linear cu
OMRON
Digital temperature controller
E5AC-CX4ASM-013
OMRON Digital temperature controller E5AC-CX4ASM-013
Size: 96 x 96mm. Control output 1: linear cu