OMRON
Home >> Download >> OMRON >> Manual Download >> E5AN-R3H03T-W-FLK-N User's Manual ()

E5AN-R3H03T-W-FLK-N User's Manual ()

Brand: OMRON
Product model: E5AN-R3H03T-W-FLK-N
Name: Temperature Controller
Sort: User's Manual
File language: English
File size: 1.17MB
Sensing method: Through-beam (Emitter + Receiver).
Connection method: Pre-wired (2 m).
Sensing distance: 300 mm.
Operation mode: Light-ON.
Model: NPN output.
Makes Mounting and Installation Simpler and Smoother.
Suitable for Applications in the Rechargeable Battery Industry. Size: 96 × 96 mm.
Control type: Basic control (1 loop) E5AN-R3H03T-W-FLK-N User's Manual.
Control mode: Single-loop standard control Single-loop heating and cooling control E5AN-R3H03T-W-FLK-N
Outputs(control/transfer): 2 points: Pulse voltage and Pulse voltage/current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, No.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity E5AN-R3H03T-W-FLK-N User's Manual.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5AN-R3H03T-W-FLK-N User's Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5AN-R3H03T-W-FLK-N Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AN-R3H03T-W-FLK-N Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Foundation type temperature controller
E5EN-C301T-W-FLK-N
OMRON Foundation type temperature controller E5EN-C301T-W-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-R3H03T-W-FLK-N
OMRON Foundation type temperature controller E5EN-R3H03T-W-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-C303T-W-FLK-N
OMRON Foundation type temperature controller E5EN-C303T-W-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5AN-R3H03TD-FLK-N
OMRON Foundation type temperature controller E5AN-R3H03TD-FLK-N
Size: 96 x 96mm. Ontology: terminal type, tem