Appearance: Shielded, M5.
Stable sensing area: 1 (2) mm.
Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V) E5CN-C2BT-W User's Manual.
Shell color: black.
Control output: linear voltage output
E5CN-C2BT-W
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products E5CN-C2BT-W User's Manual.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat E5CN-C2BT-W User's Manual.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultName: HFU (gradient temperature control) (See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sourcing).
Functions: Heater burnout alarm, None; Event inputs, 4.
Communications functions: From End Unit, Port A, RS-485; Port C, RS-422.
Input type: No input.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control ffor up to 2 groups E5CN-C2BT-W Manual.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models E5CN-C2BT-W Manual. ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise.