The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5CN-C2LU USER'S MANUAL E5CN-C2LU
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5CN-C2LU USER'S MANUAL.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: M12 (Brass); Double; Shielded (See note 2 E5CN-C2LU USER'S MANUAL. ).
Sensing distance: 4 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaseed,
Further performance improvement E5CN-C2LU Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-C2LU Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Foundation type temperature controller
E5CN-Q2H03T-FLK
OMRON Foundation type temperature controller E5CN-Q2H03T-FLK
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-R2HH03T-FLK
OMRON Foundation type temperature controller E5CN-R2HH03T-FLK
The main ody: terminal type, temperature inp
OMRON
Programmed temperature controller
E5CN-HTQQ203D-FLK
OMRON Programmed temperature controller E5CN-HTQQ203D-FLK
Size: 48 48mm, terminal type. Type: control
OMRON
Basic-type Digital Temperature Controller
E5CN-CTU
OMRON Basic-type Digital Temperature Controller E5CN-CTU
Size: 1/16 DIN. Case color: Black. Power su