Size: 96 x 96mm.
Control output 1: double relay (proportional valve).
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications E5CN-HQ2HH03-FLK User's Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure
E5CN-HQ2HH03-FLK
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately) E5CN-HQ2HH03-FLK User's Manual.
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control E5CN-HQ2HH03-FLK User's Manual. Appearance: Shielded, M12.
Sensing distance: 4 mm.
Output: NPN.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances. Appearance: Noise-resistant Models, Unshielded 34 dia.
Sensing distance: 20 mm [3 to 20 mm *].
Model: Output configuration, AC/DC 2-wire;
Operation mode, NO.
Long-distance Capacitive Sensor.
with Adjustable Sensitivity.
CE Marking for DC 3-wire models and AC/DC 2-wire models.
Noise-resistant models are also available for environments with,
strong noise. Size: 1/8DIN 48 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Temperature Input Type.
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: RS-485.
Event input: None.
A position proportional control model for the E5EZ-PRR series.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity.
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operaations) E5CN-HQ2HH03-FLK Manual.
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be perrformed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification E5CN-HQ2HH03-FLK Manual.