Brand: OMRON
Product model: E5CN-HQ2M-500
Name: OMRON E5CN-HQ2M-500 User's Manual Digital Temperature Controller Manual
Sort: User's Manual
File language: English
File size: 1.17MB
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function E5CN-HQ2M-500 User's Manual E5CN-HQ2M-500
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5CN-HQ2M-500 User's Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation E5CN-HQ2M-500 User's Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 1.
Control output 1: Relay output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±00 E5CN-HQ2M-500 Manual. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E5CN-HQ2M-500 Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Related products
OMRON
High performance temperature controller
E5CN-HQ2
OMRON High performance temperature controller E5CN-HQ2
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HQQ2BD
OMRON High performance temperature controller E5CN-HQQ2BD
Size: 48 x 48mm. Body: terminal type. Type: c
OMRON
High performance temperature controller
E5CN-HR2-W
OMRON High performance temperature controller E5CN-HR2-W
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
Programmed temperature controller
E5CN-HTR2BF
OMRON Programmed temperature controller E5CN-HTR2BF
Size: 48 48mm, terminal type. Category: con