OMRON
Home >> Download >> OMRON >> Manual Download >> E5CN-HR2M-500 User's Manual (Basic Type)

E5CN-HR2M-500 User's Manual (Basic Type)

Brand: OMRON
Product model: E5CN-HR2M-500
Name: Temperature Controller
Sort: User's Manual (Basic Type)
File language: English
File size: 6.14MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-HR2M-500 User's Manual.
Ideal for the thermal input devices of Temperature Controllers E5CN-HR2M-500
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5CN-HR2M-500 User's Manual.
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5CN-HR2M-500 User's Manual.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Single-loop standard control Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Pulse voltage and Pulse voltage/current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, No.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using moddels with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5CN-HR2M-500 Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,

root calculation and broken-line approximation) E5CN-HR2M-500 Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.
Related products
OMRON
Programmed temperature controller
E5CN-HTV2
OMRON Programmed temperature controller E5CN-HTV2
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTQQ2FD
OMRON Programmed temperature controller E5CN-HTQQ2FD
Size: 48 48mm, terminal type. Type: control
OMRON
Programmed temperature controller
E5CN-HTV2B
OMRON Programmed temperature controller E5CN-HTV2B
Size: 48 48mm, terminal type. Category: con
OMRON
High performance temperature controller
E5CN-HQ2H01-FLK
OMRON High performance temperature controller E5CN-HQ2H01-FLK
Size: 48 x 48mm. Body: terminal type. Categor