OMRON
Home >> Download >> OMRON >> Manual Download >> E5CN-HTQ2H03-FLK User's Manual ()

E5CN-HTQ2H03-FLK User's Manual ()

Brand: OMRON
Product model: E5CN-HTQ2H03-FLK
Name: Temperature Controller
Sort: User's Manual
File language: English
File size: 6.25MB
Sensing method: Diffuse-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 700 mm.
Functions: Timer Self Diagnosis Turbo.
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Size: 96 x 96mm.
Category: power AC100 ~ 240V with E5CN-HTQ2H03-FLK User's Manual.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode E5CN-HTQ2H03-FLK
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input E5CN-HTQ2H03-FLK User's Manual.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E5CN-HTQ2H03-FLK User's Manual.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio tyype E5CN-HTQ2H03-FLK Manual. Sensing method: Through-beam.
Connection method: Pre-wired Connector (M8, 4 pins).
Sensing distance: 25 mm.
No. of opti- cal axes: 2.
Model: NPN output.
Photoelectric Sensor with Grooved.
Design and Easy Settings . E5CN-HTQ2H03-FLK Manual.
Groove-type Sensor with groove width of 25 mm.
Models are available with one or two light axes.
Models are available with M8 pre-wired connectors.
Related products
OMRON
Programmed temperature controller
E5CN-HTQQ203-FLK
OMRON Programmed temperature controller E5CN-HTQQ203-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTQ2HBD
OMRON Programmed temperature controller E5CN-HTQ2HBD
Size: 48 48mm, terminal type. Type: control
OMRON
Programmed temperature controller
E5CN-HTQ2H03-FLK
OMRON Programmed temperature controller E5CN-HTQ2H03-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTQ2HH03D-FLK
OMRON Programmed temperature controller E5CN-HTQ2HH03D-FLK
Size: 48 48mm, terminal type. Type: control