Size: 48 x 96mm.
Control output 1: voltage.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 4.
Communication: -.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications E5CN-RQ203L-FLK USER'S MANUAL.
Can be set up to 8 procedures (mode) x 32 (step) procedure
E5CN-RQ203L-FLK
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately) E5CN-RQ203L-FLK USER'S MANUAL.
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control E5CN-RQ203L-FLK USER'S MANUAL. Sensing method: Retro reflective.
Appearance: Horizontal.
Connection method: Pre-wired (2 m).
Sensing distance: 1m [100 mm].
Model: PNP output.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and other transparent containers, --.
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / connector type.
Shape: non shield, M8.
Detection range: 2mm.
Output configuration: PNP.
Action mode: NC. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furrther performance improvement E5CN-RQ203L-FLK Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-RQ203L-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.