Power supply voltage: 5 to 24 VDC.
Output configuration: Open-collector output (NPN).
Resolution (pulses/rotation): 10, 20, 30, 40, 50, 60, 100,
200, 300, 360, 400, 500, 600; 720, 800, 1,000, 1,024,
1,200, 1,500, 1,800, 2,000.
General-purpose Encoder with.
External Diameter of 50 mm.
Incremental model E5CN-Y2L User's Manual.
External diameter of 50 mm.
Resolution of up to 2,000 ppr.
IP64 (improved oil-proof construction with sealed bearings)
E5CN-Y2L
Side or back connections are possible. Pre-wired Models with cable,
connected at an angle. Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: Pre-wired.
Body material: Stainless steel.
Thread length (overall length): 49 (62).
Output configuration: PNP E5CN-Y2L User's Manual.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Sensor type: Through-beam E5CN-Y2L User's Manual.
Sensing distance: 20 m.
Connection method: M12 connector.
Model: PNP output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status off the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-Y2L Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CN-Y2L Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.