OMRON
Home >> Download >> OMRON >> Manual Download >> E5CN-Y2L User's Manual (Communications Functions)

E5CN-Y2L User's Manual (Communications Functions)

Brand: OMRON
Product model: E5CN-Y2L
Name: Digital Temperature Controller
Sort: User's Manual (Communications Functions)
File language: English
File size: 1.00MB
Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output) E5CN-Y2L User's Manual.
Communication: RS-232C.
New program type E5CN-Y2L
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms E5CN-Y2L User's Manual.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E5CN-Y2L User's Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Sensor type: Diffuse-reflective.
Sensing distance: 300 mm.
Connection method: pre-wired.
Model: NPN output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. Size: M12 (Brass); Double; Unshielded E5CN-Y2L Manual.
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Detection modee: diffuse reflection type E5CN-Y2L Manual.
Detection range: 50mm.
Usage: slender type,
Small thin space probe;
Interference prevention function with close installation
Related products
OMRON
Programmed temperature controller
E5CN-HTC2
OMRON Programmed temperature controller E5CN-HTC2
Size: 48 48mm, terminal type. Category: con
OMRON
Foundation type temperature controller
E5CN-R2HH03TD-FLK
OMRON Foundation type temperature controller E5CN-R2HH03TD-FLK
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-Y2T
OMRON Foundation type temperature controller E5CN-Y2T
The main ody: terminal type, temperature inp
OMRON
Programmed temperature controller
E5CN-HTR2H01-FLK
OMRON Programmed temperature controller E5CN-HTR2H01-FLK
Size: 48 48mm, terminal type. Category: con