Type: 3 wire, shielded.
Shape: 4.
Detection range: 0.8mm.
Connection mode: lead type (2m).
Wire specification: PVC (oil resistant).
Action mode NC.
NPN output.
Proximity sensors for preferred world top performance and quality.
Standard type of magnetic metal detection.
Rich variety.
According to the conditions to choose the most suitable models E5EN-CY3BT-N User's Manual.
Anti interference function of different frequency range models
E5EN-CY3BT-N
Has excellent environmental performance.
Standard wire material for oil resistant PVC.
Test face using cutting oil material.
Standard wire jacket. E32-T21L type: special beam type; long range / high function,
Specialty: M3 screws (small),
Shape / detection distance (mm): 540; 440; 250 (100),
Bending radius (mm): R10 E5EN-CY3BT-N User's Manual.
Standard test object (minimum test object) (mm) 1: 0.9 (0.005),
Fiber element for meeting diversified needsSize: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Size: DIN 1/8, 48 x 96 x 60mm E5EN-CY3BT-N User's Manual.
Power supply voltage: AC100 ~ 240V.
Input type: Platinum resistance.
Alarm points: 1 points.
Control output: voltage output (for driving SSR).
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication aadapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5EN-CY3BT-N Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5EN-CY3BT-N Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).