Size: 48 * 48mm, terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: - E5EN-HSS3BFMD-500 User's Manual.
Event input points: -.
Transfer output: transfer output (special terminal)
E5EN-HSS3BFMD-500
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E5EN-HSS3BFMD-500 User's Manual.
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) E5EN-HSS3BFMD-500 User's Manual.
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Temperature range: -40.0 ~ 40.
Positive / reverse action: positive action (cooling).
Adjustment mode: OFF, ON action.
With the aid of microcomputer, the temperature control can be realized with high precision (0.1 degrees C).
Combined use of control equipment, adjustable sensitivity.
Attached to facilitate the energy saving operation of the set value conversion function, as well as ease of operation to stop the control function. Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection range: red light 300mmm.
Output mode: NPN output. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5EN-HSS3BFMD-500 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EN-HSS3BFMD-500 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.