Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC *1 .
Rated input voltage: 5 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”) G9SX-LM224-F10-RC USER'S MANUAL.
Socket type, same size as LY Power Relays
G9SX-LM224-F10-RC
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Slim-styled I/O Relay Saves Space in Panel.
SPST-NO, SPST-NC, and SPDT contact forms available for,
output (SPST-NO only for input).
Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
All Output Relays provide a long endurance (1,000,000,
operations at 5 A), while all Input Relays provide microswitching,
power (100 μA at 1 V) G9SX-LM224-F10-RC USER'S MANUAL.
Approved by UL and CSA standards. Type: Standard.
Sealing: Flux-tight.
Poles: 4 poles.
Contact configuration: 3PST-NO, SPST-NC.
Rated voltage: 12, 18, 21, 24, 48, 110 VDC.
Compact, Slim Relays Conforming to,
EN Standards.
Relays with forcibly guided contacts,
(EN50205 Class A, certified by VDE) G9SX-LM224-F10-RC USER'S MANUAL.
Supports the CE marking of machinery (Machinery Directive).
Helps avoid hazardous machine status when used as part of,
an interlocking circuit.
Four-pole and six-pole Relays are available.
The Relay’s terminal arrangement simplifies PWB pattern design.
Reinforced insulation between inputs and outputs.
Reinforced insulation between some poles of different polarity. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 45 A, 100 to 240 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surgee pass protection improved surge dielectric strength,
for output currents G9SX-LM224-F10-RC Manual. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIIN Track mounting types mount to DIN Track G9SX-LM224-F10-RC Manual.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).