OMRON
Home >> Download >> OMRON >> Manual Download >> G9SX-LM224-F10-RT USER'S MANUAL ()

G9SX-LM224-F10-RT USER'S MANUAL ()

Brand: OMRON
Product model: G9SX-LM224-F10-RT
Name: CPU Unit
Sort: USER'S MANUAL
File language: English
File size: 1.19MB
Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common G9SX-LM224-F10-RT USER'S MANUAL.
Output indicators: LED display (yellow) G9SX-LM224-F10-RT
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No G9SX-LM224-F10-RT USER'S MANUAL.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing G9SX-LM224-F10-RT USER'S MANUAL.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators G9SX-LM224-F10-RT Manual. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions G9SX-LM224-F10-RT Manual.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.
Related products
OMRON
Low-speed Monitoring Unit
G9SX-LM224-F10-RC
OMRON Low-speed Monitoring Unit G9SX-LM224-F10-RC
Safety instantaneous output: 2 Semiconductor
OMRON
Low-speed Monitoring Unit
G9SX-LM224-F10-RT
OMRON Low-speed Monitoring Unit G9SX-LM224-F10-RT
Safety instantaneous output: 2 Semiconductor