Home >> Download >> OMRON >> Manual Download >> H7CN-YLN User's Manual ()

H7CN-YLN User's Manual ()

Brand: OMRON
Product model: H7CN-YLN
Name: Digital Controllers
Sort: User's Manual
File language: English
File size: 2.10MB
Type: H5CZ.
Time specifications: Timer Mode, A-2: Power ON Delay I,
b: Repeat cycle 1, E: Interval, Z: ON/OFF-duty-adjustable flicker,
Twin Timer Mode, toff: Flicker OFF Start 1, ton: Flicker ON Start 1.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7CN-YLN User's Manual H7CN-YLN
External connections: 8-pin socket.
Inputs: None.
Outputs: Contact output (time-limit SPDT + instantaneous SPDT) Models with, instantaneous contact outputs H7CN-YLN User's Manual.
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circuits are isolated for safety and reliability.
Set value limit function prevents unexpected operation of output devices H7CN-YLN User's Manual.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer or,
the load.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection. DIN 48 X 48-mm Power OFF-delay Timer.
Long power OFF-delay times;
S-series: up to 12 seconds,
M-series: up to 12 minutes.
Models with forced-reset input are available.
11-pin and 8-pin models are available. Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A-2: Power ON Delay I, b: Repeat cycle 1,
E: Interval, Z: ON/OFF-duty-adjustable flicker, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1 H7CN-YLN Manual.
External connections: 8-pin socket.
Input: None.
Output: Contact output (time-limit SPDT + instantaneous SPDT),
Models with instantaneous contact outputs H7CN-YLN Manual.
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.
Related products
OMRON
Solid-state Counter
H7CN-XLN
OMRON Solid-state Counter H7CN-XLN
Classification: Preset Counter. Input signal
OMRON
Solid-state Counter
H7CN-YLNM
OMRON Solid-state Counter H7CN-YLNM
Classification: Preset Counter. Input signal
OMRON
Solid-state Counter
H7CN-AHN
OMRON Solid-state Counter H7CN-AHN
Classification: Preset Counter. Input signal
OMRON
Solid-state Counter
H7CN-TXH
OMRON Solid-state Counter H7CN-TXH
Classification: Totalizing Counter. Input si