Brand: OMRON
Product model: K3GN-NDC-L2
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 1.45MB
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3GN-NDC-L2 User's Manual.
Digital rotating pulse meter with high speed measurement for 50kHz K3GN-NDC-L2
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement.
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control K3GN-NDC-L2 User's Manual.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output K3GN-NDC-L2 User's Manual.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicateed from the start of operation K3GN-NDC-L2 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3GN-NDC-L2 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
1/32 DIN Digital Panel Meter
K3GN-PDC-FLK DC24V
OMRON 1/32 DIN Digital Panel Meter K3GN-PDC-FLK DC24V
Supply voltage: 24 VDC. Input type: DC volta
OMRON
1/32 DIN Digital Panel Meter
K3GN-NDT1-L2 DC24V
OMRON 1/32 DIN Digital Panel Meter K3GN-NDT1-L2 DC24V
Supply voltage: 24 VDC. Input type: DC volta
OMRON
1/32 DIN Digital Panel Meter
K3GN-NLC-FLK DC24V
OMRON 1/32 DIN Digital Panel Meter K3GN-NLC-FLK DC24V
Supply voltage: 24 VDC. Input type: DC volta
OMRON
1/32 DIN Digital Panel Meter
K3GN-NDC-FLK DC24V
OMRON 1/32 DIN Digital Panel Meter K3GN-NDC-FLK DC24V
Supply voltage: 24 VDC. Input type: DC volta