Output method: Analog resolution: 1/6000.
Analog Inputs: 2.
Analog Outputs: 1.Model : CV500-CN232.
Cable I / O connection.
20m cable length.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-422A/485 ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave CJ1W-SCU21-V1 REFERENCE MANUAL
CJ1W-SCU21-V1
No. of unit numbers allocated: 1.
Current consumption : 5V, 0 CJ1W-SCU21-V1 REFERENCE MANUAL. 40A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol. Protector for Expansion I/O Rack IOIF connector CV500-COV02CPU Bus Cable (Expansion CPU Rack) 0 CJ1W-SCU21-V1 REFERENCE MANUAL. 6 m (L) CV500-CN611Name: MIL Connector Type.
Specifications: Analog inputs; 4 inputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: C500-BC061(3G2A5-BC061).
6 slots(5 linkable slots).
C500-ID Special I/O Unit ID Sensor Unit Long-distance C500-IDS02-V1.Name: MIL Connectors.
Specifications: Inputs;
32 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CJ1W-SCU21-V1 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ1W-SCU21-V1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.