CPU Unit: CP1L-M CPU Units with 60 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 36; Output, 24.
Standards: UC1, N, L, CE CP1W-16ER I/O Wiring Diagram.
High Performing Programmable Controller with Embedded Ethernet
CP1W-16ER
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Number of outputs: 8 pts.
Max. switch-ing capacity: 1.0 A at 24 V DC.
External connector: Terminal block CP1W-16ER I/O Wiring Diagram.
Weight: 240 g max.100 to 120/200 to 240 VAC (switchable), Wired.C500-OA I/O Unit Triac Output 24 pts C500-OA223(3G2A5-OA223).
AC250V 1A.Model : CV500-CIF21.
When connected to form C500-NC222.Output type: Transistor sinking.
Inputs points: 24 points.
Outputs points: 16 points.CPU Unit: CP1L-L CPU Units with 14 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 8; Output, 6 CP1W-16ER I/O Wiring Diagram.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. C500-ID Special I/O Unit ID Sensor Unit For the C500-IDS22 C500-IDA22.CV500-BS CPU Bus Unit BASIC Unit CV500-BSC41.
RS-232C: 2 ports.
Centronics: 1 port.
(w/EEPROM).Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material costt can be reduced CP1W-16ER Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1W-16ER Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.