C500-CT/3G2A5-CT Special I/O Unit High-speed Counter 50 kcps 1 pts C500-CT001(3G2A5-CT001).Power supply: AC power supply.
Output method: Transistor output sink type.
Inputs points: 18 points.
Outputs points: 12 points.C500-ID I/O Unit DC Input 16 pts 8 pts/common C500-ID112.
DC5-12V 6mA.CVM1-CL Accessory MODULE, CONTROLLER LINK, 62 CPM1A-10CDT-A-V1 I/O Wiring Diagram. 5FIB CVM1-CLK52.Name: Heat/Cool Temperature Control Module
CPM1A-10CDT-A-V1
Model: C200H-TV101.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Transistor output.Name: Clamp Terminal Blocks.
Specifications: Outputs; 16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CPM1A-10CDT-A-V1 I/O Wiring Diagram.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CPM1A-10CDT-A-V1 I/O Wiring Diagram. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space coompared,
with previous systems CPM1A-10CDT-A-V1 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CPM1A-10CDT-A-V1 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.