Brand: OMRON
Product model: CRT1-VAD02SD
Name: analog i/o slave
Sort: Instruction manual
File language: English
File size: 0.68MB
Inputs: 8I/O link input bits.
Outputs: 8I/O link input bits.Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 8 outputs;
Maximum switching capacity, 24VDC,
0.5A Short-circuit protection;
Commons, 8 points, 1 common;
External connection, Removable terminal block CRT1-VAD02SD Instruction manual.
No. of words allocated: 1 word CRT1-VAD02SD
Current consumption: 5V, 0.10A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system CRT1-VAD02SD Instruction manual.
throughput. Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 64 outputs;
Maximum switching capacity, 12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0.17A; 24V, -- CRT1-VAD02SD Instruction manual.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.
Model: C200HW-COM01.
Specifications: Communications port for Controller Link, SYSMAC LINK Units.Unit type: CJ1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24 VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumpption: 5V, 0 CRT1-VAD02SD Manual. 08A; 24V, --.
Standards: UC1, N, L, CE.
High-speed Starting of I/O InterruptTasks.
Use Up to Two Units for a Total of Up,
to 32 Interrupt Inputs.
Receive inputs to start I/O interrupt tasks.
When the Interruptt Input Unit receives an input,
the CPU Unit will interrupt execution of the,
cyclic tasks in the normal CRT1-VAD02SD Manual.
program and execute an I/O interrupt task.
Related products
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-VOD32ML
OMRON CompoNet Gateway Unit for CC-Link CRT1-VOD32ML
Name: MIL Connectors. Specifications: Output
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-VID32ML-1
OMRON CompoNet Gateway Unit for CC-Link CRT1-VID32ML-1
Name: MIL Connectors. Specifications: Inputs
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-VOD16ML-1
OMRON CompoNet Gateway Unit for CC-Link CRT1-VOD16ML-1
Name: MIL Connectors. Specifications: Output
OMRON
Analog I/O Slave Units
CRT1-VDA02ML
OMRON Analog I/O Slave Units CRT1-VDA02ML
Name: MIL Connector Type. Specifications: An