OMRON
Home >> Download >> OMRON >> Manual Download >> D4B-1115N INSTRUCTION sheet ()

D4B-1115N INSTRUCTION sheet ()

Brand: OMRON
Product model: D4B-1115N
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.32MB
Operation indicator: With operating indication; Standard load.
Ratings: 5 A at 125 VAC.
Actuator: Adjustable rod lever.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4B-1115N INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4B-1115N
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4B-1115N INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Actuator: Arm lever.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door D4B-1115N INSTRUCTION sheet.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Actuator: Roller lever (stainless steel roller).
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the levver D4B-1115N Manual.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4B-1115N Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Related products
OMRON
Safety Limit Switch
D4B-4515N
OMRON Safety Limit Switch D4B-4515N
Actuator: Roller lever stainless steel rolle
OMRON
Safety Limit Switch
D4B-4A11N
OMRON Safety Limit Switch D4B-4A11N
Actuator: Roller lever resin roller. Condu
OMRON
Safety Limit Switch
D4B-4111N
OMRON Safety Limit Switch D4B-4111N
Actuator: Roller lever resin roller. Condu
OMRON
Safety Limit Switch
D4B-2A71N
OMRON Safety Limit Switch D4B-2A71N
Actuator: Roller plunger. Conduit openings: