OMRON
Home >> Download >> OMRON >> Manual Download >> D4N-3226 INSTRUCTION sheet ()

D4N-3226 INSTRUCTION sheet ()

Brand: OMRON
Product model: D4N-3226
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ D4N-3226 INSTRUCTION sheet.
Conduit size (See Note.): 1/2-14NPT D4N-3226
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) D4N-3226 INSTRUCTION sheet.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors D4N-3226 INSTRUCTION sheet. Type: Welding / wire type, with right column.
Drive rod: leaf Shibai rod type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Flexible rod, Plastic rod.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide stanndard operating temperature range:
-40°C to +100°C (standard type) D4N-3226 Manual.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4N-3226 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
Related products
OMRON
Safety Limit Switch
D4N-4F20
OMRON Safety Limit Switch D4N-4F20
Actuator: Roller lever resin lever, resin ro
OMRON
Pull-reset Safety Limit Switch
D4N-1A2HR
OMRON Pull-reset Safety Limit Switch D4N-1A2HR
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-8131
OMRON Safety Limit Switch D4N-8131
Actuator: Plunger. Conduit size: 2-conduit
OMRON
Safety Limit Switch
D4N-422H
OMRON Safety Limit Switch D4N-422H
Actuator: Adjustale roller lever, form lock