Actuator: Adjustable rod lever.
Conduit openings: M20.
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts D4N-3B87 INSTRUCTION sheet.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
D4N-3B87
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) D4N-3B87 INSTRUCTION sheet.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: M20 D4N-3B87 INSTRUCTION sheet.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC.
Conduit opening: G1/2.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
SSelectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility D4N-3B87 Manual.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for eithher standard loads or microloads D4N-3B87 Manual.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available.