OMRON
Home >> Download >> OMRON >> Manual Download >> D4N-3FRE INSTRUCTION sheet ()

D4N-3FRE INSTRUCTION sheet ()

Brand: OMRON
Product model: D4N-3FRE
Name: pull-reset safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Input type: Thermocouple input.
I/O points: 4 inputs allocated 4 input words at the Master Unit,
(8 input words allocated when 1/100 display mode is selected).
Temperature Input Terminal with Smart Functionality.
The Temperature Input Terminal can be used with almost the same functionality as a.
Analog Input Terminal, such as with scaling and comparator functions D4N-3FRE INSTRUCTION sheet.
Enhanced performance is provided with functionality specific to the Temperature,
Input Terminal, such as the recording the operating time in a preset temperature,
range and temperature difference detection between input channels D4N-3FRE Type: Welding / wire type, M3 screw mounting.
Drive rod: needle shaped button type.
Terminal specifications: with wire, under the lead D4N-3FRE INSTRUCTION sheet.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free D4N-3FRE INSTRUCTION sheet. Actuator: Shaft.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Type of drive rod: one-way action roller type (vertical motion).
Conduit size: single catheter type, M20.
Built in switch structure: sllow motion (2NC) D4N-3FRE Manual.
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forcedd open action structure D4N-3FRE Manual.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-1B62R
OMRON Pull-reset Safety Limit Switch D4N-1B62R
Actuator: One-way roller arm lever horizonta
OMRON
Safety Limit Switch
D4N-2C72
OMRON Safety Limit Switch D4N-2C72
Actuator: One-way roller arm lever vertical
OMRON
Safety Limit Switch
D4N-2D25
OMRON Safety Limit Switch D4N-2D25
Actuator: Roller lever metal lever, metal ro
OMRON
Pull-reset Safety Limit Switch
D4N-8D72R
OMRON Pull-reset Safety Limit Switch D4N-8D72R
Actuator: One-way roller arm lever vertical