OMRON
Home >> Download >> OMRON >> Manual Download >> D4N-5C72R INSTRUCTION sheet ()

D4N-5C72R INSTRUCTION sheet ()

Brand: OMRON
Product model: D4N-5C72R
Name: pull-reset safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: G1/2.
1NC/1NO (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking D4N-5C72R INSTRUCTION sheet.
Certified by UL and CSA standards D4N-5C72R
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operation prevented by special Operation Key.
Wide temperature range specifications: −40 to 80°C D4N-5C72R INSTRUCTION sheet.
Degree of protection of the switch box: IP67 (EN60947-5-1). Specifications: I/O; NPN (input: + common,
output: - common); 8 inputs/8 outputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from external source for outputs.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect D4N-5C72R INSTRUCTION sheet.
Sensors with Pre-wired Cables without Using,
Special Tools.
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,
industry-standard sensor connectors.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection. Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models witth 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4N-5C72R Manual.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4N-5C72R Manual.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
Related products
OMRON
Safety Limit Switch
D4N-4225
OMRON Safety Limit Switch D4N-4225
Actuator: Roller lever resin lever, metal ro
OMRON
Safety Limit Switch
D4N-1B62
OMRON Safety Limit Switch D4N-1B62
Actuator: One-way roller arm lever horizonta
OMRON
Safety Limit Switch
D4N-1C2H
OMRON Safety Limit Switch D4N-1C2H
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-1226
OMRON Safety Limit Switch D4N-1226
Actuator: Roller lever resin lever, earing