OMRON
Home >> Download >> OMRON >> Manual Download >> D4N-5D32 INSTRUCTION sheet ()

D4N-5D32 INSTRUCTION sheet ()

Brand: OMRON
Product model: D4N-5D32
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4N-5D32 INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4N-5D32
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4N-5D32 INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action) D4N-5D32 INSTRUCTION sheet.
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key innsertion point D4N-5D32 Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-5D32 Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-2C72R
OMRON Pull-reset Safety Limit Switch D4N-2C72R
Actuator: One-way roller arm lever vertical
OMRON
Safety Limit Switch
D4N-1C2G
OMRON Safety Limit Switch D4N-1C2G
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-8F22
OMRON Safety Limit Switch D4N-8F22
Actuator: Roller lever metal lever, resin ro
OMRON
Pull-reset Safety Limit Switch
D4N-9B31R
OMRON Pull-reset Safety Limit Switch D4N-9B31R
Actuator: Plunger. Conduit size: 1-conduit