Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Sealed pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4N-6B22 INSTRUCTION sheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
D4N-6B22
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4N-6B22 INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Type: Welding / wire type, with right column.
Driving rod: swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1c D4N-6B22 INSTRUCTION sheet.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Actuator: Arm lever.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-dooor D4N-6B22 Manual.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBBB contacts are also available D4N-6B22 Manual.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.