OMRON
Home >> Download >> OMRON >> Manual Download >> D4N-7A2GR INSTRUCTION sheet ()

D4N-7A2GR INSTRUCTION sheet ()

Brand: OMRON
Product model: D4N-7A2GR
Name: pull-reset safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @ D4N-7A2GR INSTRUCTION sheet.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock D4N-7A2GR
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) D4N-7A2GR INSTRUCTION sheet.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors D4N-7A2GR INSTRUCTION sheet. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Roller lever *1, Center neutral operation.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standdard operating temperature range:
-40°C to +100°C (standard type) D4N-7A2GR Manual.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4N-7A2GR Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
Related products
OMRON
Safety Limit Switch
D4N-8B22
OMRON Safety Limit Switch D4N-8B22
Actuator: Roller lever resin lever, resin ro
OMRON
Pull-reset Safety Limit Switch
D4N-6B31R
OMRON Pull-reset Safety Limit Switch D4N-6B31R
Actuator: Plunger. Conduit size: 2-conduit
OMRON
Safety Limit Switch
D4N-4F32
OMRON Safety Limit Switch D4N-4F32
Actuator: Roller plunger. Conduit size: 1-co
OMRON
Safety Limit Switch
D4N-6D2H
OMRON Safety Limit Switch D4N-6D2H
Actuator: Adjustale roller lever, form lock