Actuator: Roller lever (Metal lever, resin roller).
Cable length: 1 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 1NC/1NO (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model) D4N-8B20R INSTRUCTION sheet.
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available
D4N-8B20R
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Specifications: I/O, PNP (input: - common, output: + common), 16 inputs/16 outputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector D4N-8B20R INSTRUCTION sheet.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws. Actuator: Adjustable roller lever, form lock (metal lever, rubbe roller).
Conduit size: 1-conduit; Pg13 D4N-8B20R INSTRUCTION sheet. 5.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Pin plunger.
Type: M5.
Operation Indicator: None.
Repeat accuracy: 1 µm max.
Operating force OF max: 0.49 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 1 m.
Degree of protection: IP40.
High-precision Switch for Detecting Micron-unit,
Displacemennt D4N-8B20R Manual.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes.
Direct input posssible to microprocessors and,
programmable controllers D4N-8B20R Manual.
A version with screw-type cable connector available,