OMRON
Home >> Download >> OMRON >> Manual Download >> D4NH-1CAS INSTRUCTION sheet ()

D4NH-1CAS INSTRUCTION sheet ()

Brand: OMRON
Product model: D4NH-1CAS
Name: safety-door hinge switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.47MB
Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ D4NH-1CAS INSTRUCTION sheet.
Conduit size (See Note D4NH-1CAS): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) D4NH-1CAS INSTRUCTION sheet.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4NH-1CAS INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors. Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Roller lever, high sensitivity.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Caable lengths of 3 and 5 m available on standard models D4NH-1CAS Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4NH-1CAS Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
Related products
OMRON
Safety-door Hinge Switch
D4NH-2CAS
OMRON Safety-door Hinge Switch D4NH-2CAS
Actuator: Shaft. Conduit size: 1-conduit G1
OMRON
Safety-door Hinge Switch
D4NH-1CAS
OMRON Safety-door Hinge Switch D4NH-1CAS
Actuator: Shaft. Conduit size: 1-conduit Pg
OMRON
Safety-door Hinge Switch
D4NH-6BBC
OMRON Safety-door Hinge Switch D4NH-6BBC
Actuator: Arm lever. Conduit size: 2-conduit
OMRON
Safety-door Hinge Switch
D4NH-8EBC
OMRON Safety-door Hinge Switch D4NH-8EBC
Actuator: Arm lever. Conduit size: 2-conduit