Actuator: Arm lever.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms D4SL-N2FFA-DN INSTRUCTION sheet.
1NC/1NO, and 2NC. Models with MBB contacts are also available
D4SL-N2FFA-DN
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Supports ISO 13849-1 (PLe/Safety Category 4).
Can be used on higher risk level applications,
by connecting to Safety Controllers.
Supports a wide range of applications in combination with,
Safety Controller G9SP or Non-contact Door Switch,
Controller G9SX-NS@ D4SL-N2FFA-DN INSTRUCTION sheet.
Up to 30 units can be connected.
Ideal for middle to large scale device applications.
Contributes to shortening the time it takes to find,
the cause of failure by the switch''s LED display patterns.
Photocoupler monitor output allows connection to,
a general-purpose PLC (NPN type).
Compatibility with the D40A allows standardization of machine design D4SL-N2FFA-DN INSTRUCTION sheet.
Compact Non-contact Door Switch can be mounted from both sides. Power supply voltage: 24 VDC.
Connects to a Total Maximum of Eight,
Digital I/O, Analog I/O, and Relay Output,
Units Compatible with MULTIPLE I/O,
TERMINAL.
Allows flexible combinations of I/O points.
Covering a total cable length of 3 m.
DIN track mounting. Release key type: Trapped key *1.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and ttwo monitor contacts provide an,
array of monitoring patterns D4SL-N2FFA-DN Manual.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4SL-N2FFA-DN Manual.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.