OMRON
Home >> Download >> OMRON >> Manual Download >> D4SL-N2GFA-DN INSTRUCTION sheet ()

D4SL-N2GFA-DN INSTRUCTION sheet ()

Brand: OMRON
Product model: D4SL-N2GFA-DN
Name: guard lock safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.57MB
Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4SL-N2GFA-DN INSTRUCTION sheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4SL-N2GFA-DN
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger D4SL-N2GFA-DN INSTRUCTION sheet.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4SL-N2GFA-DN INSTRUCTION sheet.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models D4SL-N2GFA-DN Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4SL-N2GFA-DN Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.