OMRON
Home >> Download >> OMRON >> Manual Download >> D4SL-N3EFG-DN INSTRUCTION sheet ()

D4SL-N3EFG-DN INSTRUCTION sheet ()

Brand: OMRON
Product model: D4SL-N3EFG-DN
Name: guard lock safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.57MB
Lock method: Mechanical lock.
Conduit size: G1/2.
Voltage for solenoid: 24 VDC.
With LED indicator 2NC+ 2NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation D4SL-N3EFG-DN INSTRUCTION sheet.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid D4SL-N3EFG-DN
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened D4SL-N3EFG-DN INSTRUCTION sheet.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key for a swinging door are available D4SL-N3EFG-DN INSTRUCTION sheet.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions. Actuator: Shaft.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Flexible rod, Cat whisker.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type) D4SL-N3EFG-DN Manual.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4SL-N3EFG-DN Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)