OMRON
Home >> Download >> OMRON >> Manual Download >> D4SL-N3TFG INSTRUCTION sheet ()

D4SL-N3TFG INSTRUCTION sheet ()

Brand: OMRON
Product model: D4SL-N3TFG
Name: guard lock safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.63MB
Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever, high sensitivity.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4SL-N3TFG INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4SL-N3TFG
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4SL-N3TFG INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Measurement range: 4 mm.
Resolution: 0.4 µm.
Operating force: Approx. 0.7 N.
Five Types of Sensor for Use in a Wide.
Range of Environments D4SL-N3TFG INSTRUCTION sheet.
D5SN-S01/-S04/-S04-L Sensors have a compact and light,
weight design with an ultra-small diameter of 6 mm.
The D5SN-S01 offers a high resolution of 0.1 µm.
D5SN-M05/-M10 Sensors have a robust construction and can,
withstand a horizontal load of 5 N.
D5SN-S01/-S04/-M05/-M10 Sensors ensure IP67 degree of,
protection.
All Sensors have an insulated design. Ratings: 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable*.
Actuator: Sealed roller plunger.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cablle lengths of 3 and 5 m available on standard models D4SL-N3TFG Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
conffirmation of operation D4SL-N3TFG Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)