Unique 18-mm-dia. Capacitive Touch.
Switch with Choice of Three Actuators is.
Activated with Only a Very Slight.
Physical Contact.
Only a slight activation force is required, enabling detecting micro.
deflections, thin wires, or thin-plate conductors (e.g., steel or stainless).
Application possible for non-conductors by indirectly connecting to ground D4SL-N4PDA-DN INSTRUCTION sheet.
Instantaneous operation upon contact with extremely limited,
hysteresis for high-precision position detection
D4SL-N4PDA-DN
Diameter of only 18 mm with standard built-in amplifier, operation,
indicator, and sensitivity adjustment.
Conforms to IEC IP67 .
Freely replaceable antenna with screw mounting.
Free attachment to enable changing the antenna shape according to the application D4SL-N4PDA-DN INSTRUCTION sheet. Receptacle box: G 1/2 Conduit.
Indicator: With LED indicator (DC).
Actuator: Side plunger, Adjustable.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type) D4SL-N4PDA-DN INSTRUCTION sheet.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertiion point D4SL-N4PDA-DN Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N4PDA-DN Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.