OMRON
Home >> Download >> OMRON >> Manual Download >> DRT2-ID32BV INSTRUCTION Manual ()

DRT2-ID32BV INSTRUCTION Manual ()

Brand: OMRON
Product model: DRT2-ID32BV
Name: remote i/o terminal
Sort: INSTRUCTION Manual
File language: English
File size: 0.36MB
Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ DRT2-ID32BV INSTRUCTION Manual.
Conduit size (See Note.): M20 DRT2-ID32BV
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) DRT2-ID32BV INSTRUCTION Manual.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors DRT2-ID32BV INSTRUCTION Manual. Actuator: Roller plunger.
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Classification: Analog input.
I/O points: 4 inputs (Resolution: 6, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler function.
EEquipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function DRT2-ID32BV Manual.
Two I/O points can be allocated to any two of the followingg values: analog,
input, peak/bottom, top, valley, or rate-of-change DRT2-ID32BV Manual. Values without an,
allocated I/O point can be read with message communications.
Related products