E3F3-D86M detection method: diffuse reflection type,
Lead extraction: CN M12,
Type: metal appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyContinuation of the E6B2 high cost, value also have more choice E2E-C03SR8-WC-B2 INSTRUCTION sheet.
E6B3, E6C4 blockbuster debut! Complementary output of the first starting high anti interference
E2E-C03SR8-WC-B2
40mm diameter, shaft diameter of phi 8mm universal, with strong axial load capacity.
50mm diameter, shaft diameter of phi 10mm rugged, with strong axial load capacity,
At the same time, the use of IP65 anti drip, anti oil structure.
E6B2 complementary output will be issued over the same period E2E-C03SR8-WC-B2 INSTRUCTION sheet.
Connection length to reach a full 30m!
Resolution (pulse / rotation):10~3600P/R.
Power supply voltage: DC12 ~ 24V
Consumption current: 100mA below.
Output state: complementary output.
Maximum response frequency: 100kHz.
Output phase difference: A phase, B phase difference 90 plus or minus 45.
Starting torque: M / 10mN below (at room temperature) E2E-C03SR8-WC-B2 INSTRUCTION sheet.
Maximum allowable speed: 5000r/min.
Axial force: radial...... 120N, axial...... 50N. Protective tubing length: M6 screw.
Lead wire length: 2m.
Element type: K (CA).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuaal, RUN/STOP, alarm), interactive display PV/SV E2E-C03SR8-WC-B2 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2E-C03SR8-WC-B2 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.