Brand: OMRON
Product model: E2E-X10MY1-M1-Z
Name: proximity switch
Sort: INSTRUCTION sheet
File language: English
File size: 1.51MB
Sensing method: Narrow-beam reflective.
Connection method: Connector (M8, 4pins).
Sensing distance: 90±30 mm.
Model: PNP output.
Small 2.5-mm-diameter Spot Ideal for.
Detecting Small Workpieces.
Tiny workpieces as little as 0.1 mm in diameter can be,
detected with the 2.5-mm-dia. spot.
The narrow beam enables sensing from small slots or holes E2E-X10MY1-M1-Z INSTRUCTION sheet.
The small spot of light enables visual checking of sensing,
spot position E2E-X10MY1-M1-Z
IP67 degree of protection, mutual interference prevention,
and EN standard compliance. Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color:Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V) E2E-X10MY1-M1-Z INSTRUCTION sheet.
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E2E-X10MY1-M1-Z INSTRUCTION sheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 10 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision.
Temperature Sensors E2E-X10MY1-M1-Z Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2E-X10MY1-M1-Z Manual.
Related products
OMRON
Standard Proximity Sensor
E2E-X10ME2-M1-Z
OMRON Standard Proximity Sensor E2E-X10ME2-M1-Z
Appearance: M18. Sensing distance: 10 mm. C
OMRON
Standard Proximity Sensor
E2E-X10ME1-Z 2M
OMRON Standard Proximity Sensor E2E-X10ME1-Z 2M
Appearance: M18. Sensing distance: 10 mm. C
OMRON
Standard Proximity Sensor
E2E-X10Y1-Z 2M
OMRON Standard Proximity Sensor E2E-X10Y1-Z 2M
Appearance: M30. Sensing distance: 10 mm. C
OMRON
Standard Proximity Sensor
E2E-X10MF1-M1-Z
OMRON Standard Proximity Sensor E2E-X10MF1-M1-Z
Appearance: M18. Sensing distance: 10 mm. C