Control output 1: Linear current output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: --.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation E2EZ-X8D2-N INSTRUCTION sheet.
A Complete Range of I/O Capacities,
Functions, and Performance
E2EZ-X8D2-N
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Size: M18, Shielded.
Sensing distance: 8 E2EZ-X8D2-N INSTRUCTION sheet. 0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 61 (81).
Output configuration: PNP.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels) E2EZ-X8D2-N INSTRUCTION sheet.
Modular construction simplifies customization. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E2EZ-X8D2-N Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault