E32-D15Z type: standard type; standard,
Specialty: plane shape; head,
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsItem: Water-resistant models.
Connection method: Pre-wired (2 m).
Ratings and Specifications: Degree of protection: IP66 E2F-X1R5E1 INSTRUCTION sheet.
Model: PNP output.
Simple and Affordable Fiber Amplifier Units
E2F-X1R5E1
Reasonable price.
Use the one-key one-function feature for quick,
easy operation.
GIGA RAY for the highest level of power in this class for,
stable detection even with sensing objects with low.
reflection or large sensing objects. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3 E2F-X1R5E1 INSTRUCTION sheet. 2 dia.
Protective tubing length L: 50cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2F-X1R5E1 INSTRUCTION sheet. Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: M12 connector.
Body material: Brass.
Thread length (overall length): 49 (65).
Output configuration: NPN.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Fuurther performance improvement E2F-X1R5E1 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E2F-X1R5E1 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.