OMRON
Home >> Download >> OMRON >> Manual Download >> E3S-AT41-D INSTRUCTION sheet ()

E3S-AT41-D INSTRUCTION sheet ()

Brand: OMRON
Product model: E3S-AT41-D
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.24MB
Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog (current/voltage).
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better E3S-AT41-D INSTRUCTION sheet.
Controllers now available with analog inputs E3S-AT41-D
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available E3S-AT41-D INSTRUCTION sheet.
Note: Refer to Precautions on page 33. Sensing method: Retro-reflective with MSR function.
Connection method: Pre-wired (2 m).
Sensing distance: 4 m(100 mm).
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models E3S-AT41-D INSTRUCTION sheet.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of tthe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3S-AT41-D Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3S-AT41-D Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD43
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD43
Sensing method: Diffuse-reflective Sensors.
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AR21
OMRON Built-in Amplifier Photoelectric Sensor E3S-AR21
Sensing method: Retro-reflective Sensors. Ap
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AR31
OMRON Built-in Amplifier Photoelectric Sensor E3S-AR31
Sensing method: Retro-reflective Sensors. Ap
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AR66
OMRON Built-in Amplifier Photoelectric Sensor E3S-AR66
Sensing method: Retro-reflective Sensors. Ap