Brand: OMRON
Product model: E3S-AT71-M1J
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.24MB
Appearance: Horizontal type.
Sensing method: Reflective type.
Sensing distance: 5 mm (slot width).
Output type: NPN output.
Output configuration: Light-ON.
Photomicrosensor with light,
modulation is not influenced by,
external light.
Voltage-output models with wide operating voltage,
range (5 to 24 VDC) E3S-AT71-M1J INSTRUCTION sheet.
Fitted with an easy-to-adjust optical axis mark.
Easy adjustment and optical axis monitoring with,
a light indicator E3S-AT71-M1J Control output: relay output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type E3S-AT71-M1J INSTRUCTION sheet.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating E3S-AT71-M1J INSTRUCTION sheet.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check thhe state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3S-AT71-M1J Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E3S-AT71-M1J Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT61
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT61
Sensing method: Through-eam Sensors. Appear
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT81
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT81
Sensing method: Through-eam Sensors. Appear
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT31
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT31
Sensing method: Through-eam Sensors. Appear
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AT16
OMRON Built-in Amplifier Photoelectric Sensor E3S-AT16
Sensing method: Through-eam Sensors. Appear